Fix: ping Miotiq command=0x02 pour retrocompat avec capteurs deployés (byte 9 = 0x01)
Les capteurs en production envoient 0x01 sur le byte 9 (ancien protocol_version). Cote serveur: 0x00 et 0x01 = data normal, 0x02 = ping test. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -24,7 +24,7 @@ import sqlite3
|
||||
MIOTIQ_IP = "192.168.0.20"
|
||||
MIOTIQ_PORT = 4242
|
||||
PAYLOAD_SIZE = 100
|
||||
COMMAND_PING = 0x01
|
||||
COMMAND_PING = 0x02
|
||||
LISTEN_TIMEOUT = 15 # seconds to wait for downlink response
|
||||
|
||||
# --- Load device_id from SQLite ---
|
||||
|
||||
@@ -334,7 +334,7 @@
|
||||
<div class="card">
|
||||
<div class="card-body">
|
||||
<p class="card-text"><strong>3. Test aller-retour</strong></p>
|
||||
<p class="text-muted small mb-2">Envoie un payload ping (command=1) via UDP puis écoute la réponse descendante Miotiq (~15s).</p>
|
||||
<p class="text-muted small mb-2">Envoie un payload ping (command=2) via UDP puis écoute la réponse descendante Miotiq (~15s).</p>
|
||||
<button class="btn btn-primary" onclick="pingMiotiq()">Ping Miotiq</button>
|
||||
<div id="loading_ping_miotiq" class="spinner-border spinner-border-sm" style="display: none;" role="status"></div>
|
||||
<div id="response_ping_miotiq"></div>
|
||||
|
||||
@@ -387,7 +387,7 @@ class SensorPayload:
|
||||
self.payload[68] = status & 0xFF
|
||||
|
||||
def set_command(self, value):
|
||||
"""Set command byte (byte 9): 0x00 = normal data, 0x01 = ping test"""
|
||||
"""Set command byte (byte 9): 0x00 = normal data, 0x01 = legacy (ancien protocol_version), 0x02 = ping test"""
|
||||
self.payload[9] = value & 0xFF
|
||||
|
||||
def set_firmware_version(self, version_str):
|
||||
|
||||
@@ -13,7 +13,7 @@ etre actifs simultanement.
|
||||
## Position dans la payload
|
||||
|
||||
```
|
||||
Byte 9 : command (0x00 = data normal, 0x01 = ping test)
|
||||
Byte 9 : command (0x00 = data normal, 0x01 = legacy/ancien protocol_version, 0x02 = ping test)
|
||||
Bytes 0-8 : device_id (8 bytes) + signal_quality (1 byte)
|
||||
Bytes 10-65 : donnees capteurs
|
||||
Byte 66 : error_flags (erreurs systeme)
|
||||
|
||||