From aa71766748a9ca003329832cf2d8c8385b04062b Mon Sep 17 00:00:00 2001 From: PaulVua Date: Tue, 2 Jun 2026 17:30:21 +0200 Subject: [PATCH] v1.12.2: flag CO2_ERROR (bit 7) quand la sonde S88 est deconnectee A la demande: en plus du sentinel 0xFFFF dans le champ CO2, on remonte le defaut via error_flags byte 66 bit 7. - ERR_CO2 = 0x80 (bit 7, double sens vent/CO2 selon device_type cote serveur) - s88_disconnected -> error_flags |= ERR_CO2 dans SARA_send_data_v2.py - error_flags.md: bit 7 documente comme WIND_ERROR / CO2_ERROR Confirme par le user: le serveur lit le bit 7 comme CO2_ERROR sur ces unites. Co-Authored-By: Claude Opus 4.8 (1M context) --- VERSION | 2 +- changelog.json | 15 +++++++++++++++ loop/SARA_send_data_v2.py | 17 +++++++++++++---- loop/error_flags.md | 2 +- 4 files changed, 30 insertions(+), 6 deletions(-) diff --git a/VERSION b/VERSION index f8f4f03..6b89d58 100644 --- a/VERSION +++ b/VERSION @@ -1 +1 @@ -1.12.1 +1.12.2 diff --git a/changelog.json b/changelog.json index 2193390..009ea19 100644 --- a/changelog.json +++ b/changelog.json @@ -1,5 +1,20 @@ { "versions": [ + { + "version": "1.12.2", + "date": "2026-06-02", + "changes": { + "features": [], + "improvements": [ + "Transmission: error_flags (byte 66) bit 7 (0x80) posé quand la sonde CO2 S88 est déconnectée (s88_status=0xFF ou aucune donnée). Bit 7 = double sens selon le produit (décodage serveur par device_type): WIND_ERROR sur NebuleAir classique, CO2_ERROR sur les unités équipées CO2 (confirmé côté serveur). Nouvelle constante ERR_CO2=0x80. error_flags.md mis à jour." + ], + "fixes": [], + "compatibility": [ + "⚠ Bit 7 partagé vent/CO2: le serveur interprète selon le device_type. Sur une box qui aurait À LA FOIS girouette ET S88, conflit — ne pas activer les deux sans arbitrage serveur." + ] + }, + "notes": "Complète v1.12.1: en plus du sentinel 0xFFFF dans le champ CO2 (byte 81-82), le bit CO2_ERROR remonte explicitement le défaut. Vérifié sur pro100 (S88 muet -> error_flags bit 7 posé)." + }, { "version": "1.12.1", "date": "2026-06-02", diff --git a/loop/SARA_send_data_v2.py b/loop/SARA_send_data_v2.py index fdf80a4..29e5949 100755 --- a/loop/SARA_send_data_v2.py +++ b/loop/SARA_send_data_v2.py @@ -160,6 +160,10 @@ ERR_ENVEA = 0x10 ERR_NOISE = 0x20 ERR_MPPT = 0x40 ERR_WIND = 0x80 +# Bit 7 is dual-purpose per product (server decodes by device_type): +# NebuleAir -> WIND_ERROR, ModuleAir / CO2-equipped units -> CO2_ERROR. +# On these CO2 boxes the server reads bit 7 as CO2_ERROR (confirmed). +ERR_CO2 = 0x80 # database connection conn = sqlite3.connect("/var/www/nebuleair_pro_4g/sqlite/sensors.db") @@ -1087,8 +1091,9 @@ try: # Only transmit when the LAST reading is valid (s88_status == 0). If the # sensor is down (s88_status == 0xFF), leave bytes 81-82 at 0xFFFF (= "CO2 # sensor absent" in the Miotiq spec) instead of sending a stale value. - # NB: byte 66 (error_flags) is already full, so absence is signalled solely - # by the 0xFFFF sentinel in the CO2 field. + # Absence is signalled two ways: the 0xFFFF sentinel in the CO2 field, and + # the CO2_ERROR bit (0x80) in error_flags (byte 66) — see build below. + s88_disconnected = False if s88_sensor: print("➡️Getting S88 CO2 value") cursor.execute("SELECT * FROM data_S88 ORDER BY rowid DESC LIMIT 1") @@ -1100,9 +1105,11 @@ try: print(f"CO2 (S88): {co2_ppm} ppm") payload.set_co2(co2_ppm) else: - print(f"S88 last reading invalid (s88_status=0x{s88_status_value:02X}) -> CO2 marked absent (0xFFFF)") + s88_disconnected = True + print(f"S88 last reading invalid (s88_status=0x{s88_status_value:02X}) -> CO2 marked absent (0xFFFF), set CO2_ERROR") else: - print("No S88 data available in the database.") + s88_disconnected = True + print("No S88 data available in the database. -> set CO2_ERROR") #print("Verify SARA connection (AT)") @@ -1236,6 +1243,8 @@ try: error_flags |= ERR_NPM if noise_disconnected: error_flags |= ERR_NOISE + if s88_disconnected: + error_flags |= ERR_CO2 # bit 7, read as CO2_ERROR by the server on these units payload.set_error_flags(error_flags) # ---- Firmware version (bytes 69-71) ---- diff --git a/loop/error_flags.md b/loop/error_flags.md index 753ba3b..faede14 100644 --- a/loop/error_flags.md +++ b/loop/error_flags.md @@ -42,7 +42,7 @@ Chaque bit represente une erreur detectee par le script d'envoi (`SARA_send_data | 4 | 0x10 | ENVEA_ERROR | Capteurs Envea non detectes ou erreur serie | data_envea → valeurs a 0 | | 5 | 0x20 | NOISE_ERROR | Capteur bruit NSRT MK4 non detecte ou erreur | data_noise → valeurs a 0 | | 6 | 0x40 | MPPT_ERROR | Chargeur solaire MPPT non detecte ou erreur | data_MPPT → valeurs a 0 | -| 7 | 0x80 | WIND_ERROR | Capteur vent non detecte ou erreur | data_windMeter → valeurs a 0 | +| 7 | 0x80 | WIND_ERROR / CO2_ERROR | Double sens selon le produit (decode serveur par device_type). NebuleAir = vent non detecte. NebuleAir equipe CO2 / ModuleAir = sonde CO2 (S88) non detectee. | data_windMeter → 0 / data_S88 → s88_status=0xFF | ### Detection des erreurs