Implements power saving optimizations to extend battery life on solar-powered remote air quality sensors: - WiFi Power Saving: Disable WiFi 10 minutes after boot to save ~100-200mA - Configurable via web UI checkbox in admin panel - WiFi automatically re-enables after reboot for 10-minute configuration window - Systemd timer (nebuleair-wifi-powersave.timer) manages automatic disable - New wifi/power_save.py script checks database config and disables WiFi via nmcli - HDMI Disable: Added hdmi_blanking=2 to boot config to save ~20-30mA - Automatically configured during installation - Database: Added wifi_power_saving boolean config (default: disabled) - Uses INSERT OR IGNORE for safe updates to existing installations - UI: Added checkbox control in admin.html for WiFi power saving - Includes helpful description of power savings and behavior - Services: Updated setup_services.sh and update_firmware.sh to manage new timer Total power savings: ~120-230mA when WiFi power saving enabled 🤖 Generated with [Claude Code](https://claude.com/claude-code) Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
15 lines
298 B
Desktop File
15 lines
298 B
Desktop File
[Unit]
|
|
Description=NebuleAir WiFi Power Save Service
|
|
After=network-online.target
|
|
Wants=network-online.target
|
|
|
|
[Service]
|
|
Type=oneshot
|
|
ExecStart=/usr/bin/python3 /var/www/nebuleair_pro_4g/wifi/power_save.py
|
|
User=root
|
|
StandardOutput=journal
|
|
StandardError=journal
|
|
|
|
[Install]
|
|
WantedBy=multi-user.target
|